Furuno CSH-24F Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt powietrzny Furuno CSH-24F. Furuno CSH-24F User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 98
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - COLOR SCANNING SONAR

COLOR SCANNING SONARMODELCSH-23/23F/24/24FBack

Strona 2 - CSH-23/24/FCSH-23/24/F

5Shortening the retraction tankThe retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so thatthe transducer is placed w

Strona 3 - SAFETY INSTRUCTIONS

6Remarks for installation of retraction tank1. Make, if possible, the installation location a double bottom structure.2. Install, if possible, the tan

Strona 4 - TABLE OF CONTENTS

7Installing hull unit on retraction tankAfter welding the retraction tank and allowing sufficient time for cooling, install the hull unit asfollows:1.

Strona 5 - 1. SYSTEM CONFIGURATION

8Installing stays (anti-vibrationmeasure)Install stays from the top of the hull unit tothe ship’s hull. The stays should be angleiron with a size of 7

Strona 6 - 2. EQUIPMENT LISTS

93.2 Mounting the Display Unit/Sub-display UnitThe display unit/sub-display unit is designed for tabletop mounting. When selecting as mount-ing locati

Strona 7 - Optional Equipment

103.3 Mounting the Transmitter UnitThe transmitter unit can be mounted with or without mounting legs. For use without mountinglegs remove them and use

Strona 8 - 3. MOUNTING THE EQUIPMENT

113.6 Grounding the EquipmentGround all equipment with a suitable copper strap or ground wire. The location of the groundterminal of each unit is show

Strona 9

124. WIRING4.1 Cable ConfigurationFigure 4-1 Cable configuration

Strona 10

134.2 How to Use the Crimping Tool, Pin ExtractorA special crimping tool is necessary for connection of wires to the contact pins of the 38Pconnector.

Strona 11

144.3 Location of ConnectorsINTERFACE UNITDISPLAY UNIT *1REMOTE CONTROLTRANSMITTER UNITRECEIVER UNITRAISE/LOWER CONTROL BOXPOWER UNITDPYCY-4Figure 4-3

Strona 12

The paper used in this manualis elemental chlorine free.FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,9-52

Strona 13 - Proper installation

154.4 Fabricating Cable, Assembling Connectors Fabricating cable 00-8016-038-313-761HV (CN-A1, CN-A5 and J201) L4540AnticorrosivesheathArmorViny

Strona 14

16Clamping the cableClamp the cable where the shield is folded back onto the armor.Figure 4-6 Clamping the cableAssembling connector NSC-253P (CN-A15)

Strona 15

17Fabricating cable 54-038-000-601/SC (CN-E1)Figure 4-9 Fabricating cable 54-038-000-601/SCAssembling 38P connector1. Bundle the unused wires outside

Strona 16 - 3.6 Grounding the Equipment

18Positioning guide pinsGuide pins of the connector are used to identify the mating receptacle. Position them shownbelow.Table 4-2 Guide pins and conn

Strona 17 - 4. WIRING

19Fabricating cable 54-038-000-601/SC (CN-B2, CN-B3, CN-B4)Figure 4-14 Fabricating cable 54-038-000-601/SCAssembling 38P connector1. Bundle the unused

Strona 18 - How to use the pin extractor

20Clamping the cableSecure the cable with the cable clamp.Figure 4-16 Clamping the cableFabricating cable 10S1259 (connected to terminal board TB-B1)F

Strona 19 - 4.3 Location of Connectors

21Assembling 38P connector1. Bundle the unused wires outside the connector case.2. Fix the cover 1, taking heed of the cable outgoing direction.3. Dre

Strona 20 - (CN-A1, CN-A5 and J201)

22Fabricating cable connected to terminal board TB-D1 in Raise/Lower Control BoxFigure 4-21 Fabricating cable connected to terminal board TB-D1in Rais

Strona 21 - Assembling BNC connector

234.5 Connection of Transducer CablesThe transducer cables are supplied with connectors. Plug them into the receptacles in the re-ceiver unit, referri

Strona 22 - Assembling 38P connector

244.6 Connection of Interface Unit CS-120A With connection of navigator, the Interface Unit CS-120A and electronic fishing equipment, the function

Strona 23 - Fabricating cable DPYCY-4

iWARNINGTurn off the power at the switchboardbefore beginning the installation.Fire or electrical shock can result if thepower is left on.Do not inst

Strona 24 - Positioning guide pins

25There are six combinations of CIF/NMEA data input. Combination NMEA port J208 CIF port J204 CI/NMEA port J207 1 NMEA data - NMEA data 2 NMEA d

Strona 25 - 00-8016-020-313-703V (CN-C4)

26Connections for ES picture and FNZ markers To provide echo sounder picture and FNZ markers, connect echo sounder to J203 and net sonde to J202. T

Strona 26 - Clamping the cable

27Connections for digital indication of position, water temperature and depth The data for these readouts are taken from the equipment shown in t

Strona 27 - Fabricating cable 10S1259

28Fabrication, assembling 10P and 7P connectorsVINYL SHEATHVINYL SHEATHVINYL SHEATH(OUTER)SOLDER UNUSED CORESAND EARTH WIRE TOBRAIDED SHIELDWIND VINYL

Strona 28 - (Code No. 100-008-460)

294.7 Connection of Sub-display Unit CSH-236/236F (Option)The Sub-Display Unit CSH-236/236F is the same as the Display Unit CSH-230/230F in terms

Strona 29

304.8 Synchronizing Transmission with Other Sonars, Echo Sounders To synchronize the transmission of the CSH-23/24 series sonars to that of other s

Strona 30

31Note: To output KP to other sonar or echo sounder, wire units as follows. Figure 4-34 Connections for outputting KP to other sonar or echo sound

Strona 31 - VI-1100A

324.9 Interlocking Operation with Other SonarFunctions (range, tilt, fish mark, etc.) and remote control may be mutually interlocked withthose on othe

Strona 32 - (CS-120A)

33Connections for interlocking remote controlTo control multiple display units by one remote control box, wire units as follows.REMOTE CONTROLCONE Boa

Strona 33

345. CHANGING POWER SPECIFICATIONSThe display unit is set at the factory for connection to a ship’s mains of 110 VAC or 220 VAC.To power it by 100 VAC

Strona 34 - (Option)

iiTABLE OF CONTENTS 1. SYSTEM CONFIGURATION ... 1 2. EQUIPMENT LISTS ...

Strona 35 - Echo Sounders

356. ADJUSTMENT AND CHECK6.1 Hull Unit Check1. Press the ON switch to turn on the equipment. Con-firm that the lamps above the ON and c switcheslight.

Strona 36 - Menu setting

3612.Press the c switch. Confirm that the lamp above the switch blinks while the transducer isbeing raised, a short beep sounds when the mid limit swi

Strona 37 - DIP switch setting

374. Enter heading correction with ← or → referring to the table below for guidance. Target Location Correction SettingTarget displayed 30° to por

Strona 38 - CN-A13 CN-A14

386.4 Setting and Adjustment of the Interface Unit CS-120A DIP switch setting Navigation data and fishing data input from external equipment can be

Strona 39 - F Photo No.2017

39DP-1ON12345678Talker check (only for NMEA signal)Talker is checked.Talker is not checked.S4OFFONDepth (Echo sounder, Color Video Sounder, etc.)In

Strona 40 - 6. ADJUSTMENT AND CHECK

40Adjustment of signal level (R36, R56) 1. Set the MODE switch to E/S. 2. Turn the potentiometer R36 to suppress a noise, and the potentiometer R

Strona 41 - 6.2 Heading Adjustment

41LC fixing position priority Latitude and Longitude are set to LC with S3 on the DIP switch DP-1. 1. LC-RMA from NMEA 2. LC-RMA from CI/NMEA 3. &

Strona 42

427. PROCESSOR UNIT CSH-235/235F (BLACKBOX TYPE FOR CSH-23/23F)7.1 Installing the Unit When selecting a mounting location, consider the following

Strona 43 - CS-120A

43 7.3 Connecting cables Fabricate the cables as shown in the section “4.4 Fabricating Cable, Assembling connectors.” Connect the cables, referring

Strona 44 - 12345678

44J3J21RGB port panelScrew (4 pcs)CONE board (10P6711)RGBHVReplace each BCN connector to the same label port.BNC connector Processor unit (right s

Strona 45 - Priority for data

11. SYSTEM CONFIGURATIONSTANDARD OPTIONREMOTE CONTROL BOXCSH-116DISPLAY UNITCSH-230 (CSH-23)MONITOR (MU-151C)*orCOMMERCIAL MONITOR*SUB DISPLAY* CSH-

Strona 46

PACKING LIST10CJ-X-9851 -1 CSH-235/235K/235F/535/585/735/835N A M EO U T L I N EDESCRIPTION/CODE №Q'TY1/1ユニット UNIT操作制御部PROCESSOR UNITCSH-235000-0

Strona 47 - 7.2 Monitor

CODE NO.006-030-590TYPESP10-03201ITEM NO.NAME OF PARTOUTLINEDWG. NO. OR PERSETPERVESSPAREWORKINGQUANTITY REMARKS/CODE NO.BOX NO. P SHIP NO.SPARE

Strona 48 - 7.3 Connecting cables

CODE NO.006-030-600TYPECP10-06301略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS1/1-0 INSTALLATION MATERIALS工事材料表10CJ-X-9401+トラスタ

Strona 51 - FURUNO ELECTRIC CO.,LTD

CODE NO.000-070-208TYPESP10-03300ITEM NO.NAME OF PARTOUTLINEDWG. NO. OR TYPE NO.PERSETPERVESSPAREWORKINGQUANTITY REMARKS/CODE NO.BOX NO. P SHIP

Strona 52 - INSTALLATION MATERIALS

CODE NO.000-070-209TYPESP10-03400ITEM NO.NAME OF PARTOUTLINEDWG. NO. OR TYPE NO.PERSETPERVESSPAREWORKINGQUANTITY REMARKS/CODE NO.BOX NO. P SHIP

Strona 53

CODE NO.006-989-010-00TYPECP10-02710略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS1/4-9 INSTALLATION MATERIALS工事材料表10BW-X-9401アー

Strona 54

CODE NO.006-989-010-00TYPECP10-02710略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS2/4-9 INSTALLATION MATERIALS工事材料表10BW-X-9401クー

Strona 55

CODE NO.006-989-010-00TYPECP10-02710略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS3/4-9 INSTALLATION MATERIALS工事材料表10BW-X-9401ミカ

Strona 56

22. EQUIPMENT LISTSStandard Supply Name Type Qty Remarks CSH-230 CSH-23 CSH-230F CSH-23F CSH-2400 CSH-24 Display Unit CSH-2400F CSH-24F CSH-235 C

Strona 57

CODE NO.006-989-010-00TYPECP10-02710略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS4/4-9 INSTALLATION MATERIALS工事材料表10BW-X-9401圧着

Strona 59

CODE NO.006-959-800-00TYPECP10-03410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS1/5-3 INSTALLATION MATERIALS工事材料表10CC-X-9401コネ

Strona 60

CODE NO.006-959-800-00TYPECP10-03410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS2/5-3 INSTALLATION MATERIALS工事材料表10CC-X-9401M8

Strona 61

CODE NO.006-959-800-00TYPECP10-03410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS3/5-3 INSTALLATION MATERIALS工事材料表10CC-X-9401アイ

Strona 62

CODE NO.006-959-800-00TYPECP10-03410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS4/5-3 INSTALLATION MATERIALS工事材料表10CC-X-9401ホー

Strona 63

CODE NO.006-959-800-00TYPECP10-03410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS5/5-3 INSTALLATION MATERIALS工事材料表10CC-X-9401アー

Strona 64

CODE NO.006-030-650-00TYPECP10-06410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS1/4-1 INSTALLATION MATERIALS工事材料表10CJ-X-9402貼り

Strona 65

CODE NO.006-030-650-00TYPECP10-06410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS2/4-1 INSTALLATION MATERIALS工事材料表10CJ-X-9402コン

Strona 66

CODE NO.006-030-650-00TYPECP10-06410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS3/4-1 INSTALLATION MATERIALS工事材料表10CJ-X-9402貼り

Strona 67

2aOptional Equipment Name Type Mass(kg) Code No. Remarks FNZ Joint Box CS-170 2 - Set-down Transformer PT-400 22 - E/S Interface Unit VI-11

Strona 68

CODE NO.006-030-650-00TYPECP10-06410略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS4/4-1 INSTALLATION MATERIALS工事材料表10CJ-X-9402コン

Strona 78

33. MOUNTING THE EQUIPMENT3.1 Mounting the Hull Unit and Receiver UnitLocation of hull unitDecide the location of the hull unit through consultation w

Strona 80

Y. HataiD-3

Strona 82

Oct.31'03D-5

Strona 86

Dec. 10, '02D-9

Strona 89

4Figure 3-2 Maintenance space, example sonar compartment

Strona 95 - T.Matsuguchi

6DCBA54321相互結線図カラースキャニングソナーINTERCONNECTION DIAGRAMCOLOR SCANNING SONARCSH-23/23F/23KT.YAMASAKIT.TAKENOkgNAMETITLE名称DWG.No.SCALEAPPROVEDCHECKEDDRAWNMAS

Strona 97 - FURUNO ELECTRIC CO., LTD

FURUNO ELECTRIC CO., LTD.CBD123456AABCDEFHLLJKLMNPRSTUVXWYZAABBCCDDEEFFHHJJKKMMNNPPRRSSTT*4SHIELD シールドGRN ミドBRN チャPPPPPPPPPPPPPPPPPPBLK クロBRN チャBRN チ

Strona 98 - C1238-003- M

243A1BCTITLENAME名称DRAWNCHECKEDAPPROVEDDWG.No.SCALE MASSINTERCONNECTION DIAGRAM相互結線図CS-120AインターフェイスINTERFACE UNITC1238-003- MT.YAMASAKIT.TAKENOJ2021234

Powiązane modele: CSH-23F

Komentarze do niniejszej Instrukcji

Brak uwag