Furuno FCV-600L Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Furuno FCV-600L. Furuno FCV-600L User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2 - H3 : OCT. 7, 2002

21.2 Indications, MarkersThe figure below shows all indications and markers which may appear in the normal display.The combination displays (normal di

Strona 3 - SAFETY INSTRUCTIONS

31.3 Turning On/Off the PowerPress the POWER key to turn the power on/off. When the unit is turned on it proceeds inthe sequence shown below.Sounderdi

Strona 4 - TABLE OF CONTENTS

450k49.60.0FishschoolBottom020406080Figure 1-7 Typical 50 kHz normal display200 kHzThe higher the frequency of the ultrasonicpulse the better the reso

Strona 5 - FOREWORD

5Bottom-zoom displayThis mode expands bottom and bottom fishechoes two to five times to vertical size of thescreen, and is useful for determining bott

Strona 6 - MENU TREE

6Enlarging a nav data indicationYou can enlarge and display one of the dataindications as follows:1. Press ▲ or ▼ to select the indication youwant to

Strona 7 - SYSTEM CONFIGURATION

71.6 Selecting Display RangeThe basic range and range shifting functionsused together give you the means to select thedepth you can see on the screen.

Strona 8 - PRINCIPLE OF OPERATION

81.8 Automatic OperationAutomatic operation is useful when you arepreoccupied with other tasks and do not havetime to adjust the display.How it worksT

Strona 9 - OPERATIONAL OVERVIEW

91.10 Erasing Weak EchoesDirty water or reflections from plankton maybe painted on the display in green or light-blue. These weak echoes may be erased

Strona 10 - 1.2 Indications, Markers

101.12 A-scope DisplayThis display shows echoes at each transmis-sion with amplitudes and tone proportional totheir intensities, on the right 1/3 of t

Strona 11 - 1.5 Selecting a Display

111.14 Suppressing InterferenceInterference from other acoustic equipmentoperating nearby or other electronic equip-ment on your boat may show itself

Strona 12

C 9-52, Ashihara-cho, Nishinomiya, Japan Telephone: 0798-65-2111 Telefax: 0798-65-4200 Your Local Agent/Dealer All rights

Strona 13 - This section

121.17 AlarmsBottom alarmThe bottom alarm sounds when the bottom iswithin the alarm range set. To activate thebottom alarm the depth must be displayed

Strona 14 - 1. 23 nm

131.18 White MarkerThe white marker functions to display a par-ticular echo color in white. For example, youmay want to display the bottom echo (red-d

Strona 15 - 1.7 Adjusting the Gain

This page is intentionally left blank.

Strona 16 - Speed

152.1 Displaying the Optional Mode MenuThe Optional mode mainly contains less-of-ten used functions which once preset do notrequire frequent adju

Strona 17 - 1.11 Measuring Depth

16System menu 1 descriptionMENU: Selects system menu desired.DEPTH UNIT: Selects unit of depth mea-surement among meters, feet, fathoms, orpassi/braza

Strona 18 - 1.13 User Menu

17Note 2: Ranges must be set in numericalorder. For example, if basic range 3 is 60feet and basic range 5 is 200 feet, the basicrange which can be set

Strona 19 - Echo Colors

182.5 TVG LevelTVG (Time Varied Gain) compensates forpropagation attenuation of the ultrasonicwaves. It does this by equalizing echo pre-sentation so

Strona 20 - 1.17 Alarms

193.1 Zero LineThe zero line (sometimes referred to as thetransmission line) represents the transducer’sposition, and moves off the screen when adeep

Strona 21 - 1.18 White Marker

203.4 Surface Noise/AerationWhen the waters are rough or the boat passesover a wake, surface noise may appear nearthe zero line. As surface turbulence

Strona 22

21MAINTENANCE & TROUBLESHOOTINGDo not open the cover.There are no user-serviceable parts inside.Refer any repair work to a qualifiedtechnician.WAR

Strona 23 - OPTIONAL MODE

iiiiiiiiiiiii iSAFETY INSTRUCTIONSWARNINGKeep heater away from equipment.A heater can melt the equipment’s powercord, which can cause fire or electric

Strona 24

224.5 TroubleshootingThe table below provides simple troubleshooting procedures which you may follow to restorenormal operation. If you cannot restore

Strona 25 - 2.4 Bottom Level

234.6 TestThe test checks the ROM, RAM, color barand keyboard for proper operation. You maystart the test as follows:1. Turn on the power while pressi

Strona 26 - 0 for 200 kHz

244.8 Clearing the MemoryThe memory (all menu settings) can be clearedto start afresh. All default menu settings arerestored when the memory is cleare

Strona 27 - INTERPRETING THE DISPLAY

SP - 1 SPECIFICATIONS OF COLOR LCD SOUNDER FCV-600L This equipment is a dual-frequency (50/200 kHz) color LCD video sounder which has a large varie

Strona 28 - 3.4 Surface Noise/Aeration

SP - 2 3. I/O DATA (1) Data Format NMEA0183(Ver.1.5/2.0) (2) Input Data RMA,RMB,BWC,GLL,VTG,VHW,MTW (3) Output Data SDDBT,YCMTW,VWVHW 4. POWE

Strona 29 - 4.4 Replacing the Fuse

iiFOREWORD...iiiMENU TREE ... ivSYSTEM CONFIGURATION... vPRINCIPLE OF OPE

Strona 30 - 4.5 Troubleshooting

iiiA Word to FCV-600L OwnersCongratulations on your choice of theFURUNO FCV-600L Color LCD Sounder.We are confident you will see why theFURUNO name ha

Strona 31 - 4.7 Test Pattern

ivMENU TREEMENUESCNOISE LIMITER (OFF, NL1, NL2, NL3)CLUTTER (0~16) Default: 9MARKER (VRM,WHITE MARKER)HUE (1~9) Default:1GAIN ADJ 200kHz (-20~+20) Def

Strona 32 - 4.8 Clearing the Memory

vSYSTEM CONFIGURATIONShip's mains12-24 VDCExternal equipment(GPS navigator, etc.)TRANSDUCERSpeed, temperaturesensor (option)DISPLAYUNITFCV-600L s

Strona 33 - FCV-600L

viThe FCV-600L determines the distance be-tween its transducer and underwater objectssuch as fish, lake bottom or seabed and dis-plays the results on

Strona 34

1OPERATIONAL OVERVIEW1.1 Control DescriptionAll operations of the FCV-600L are carried out with the controls on the front panel of thedisplay unit. Al

Komentarze do niniejszej Instrukcji

Brak uwag