1. OPERATIONAL OVERVIEW 21.2 Underwater Unit 1.2.1 Components of the underwater unit The underwater unit mainly consists of a red polyurethane case

Strona 3 - SAFETY INSTRUCTIONS

1. OPERATIONAL OVERVIEW 31.2.3 Mounting the underwater unit on the trawl Usually the underwater unit is fixed either on the head rope of the trawl o

Strona 4 - TABLE OF CONTENTS

1. OPERATIONAL OVERVIEW 4 1.3 Starting Up, Shutting Down 1.3.1 Starting up 1. Check the connection between the underwater unit and the winch. 2. M

Strona 5 - FOREWORD

1. OPERATIONAL OVERVIEW 51.4 Catch Sensor CS-400 (option) Mounted on the cod end of the trawl, the catch sensor monitors the catch of fish. Four cat

Strona 6 - SYSTEM CONFIGURATION

1. OPERATIONAL OVERVIEW 61.5 Screen Layout The fully configured TS-331A provides five viewing windows (Vertical sonar image, Depth/water temperature

Strona 7 - OPERATIONAL INFORMATION

1. OPERATIONAL OVERVIEW 7Note 2: Certain devices or sensors can be manually disabled by turning them off from the Options menu. See the figure below.

Strona 8

1. OPERATIONAL OVERVIEW 8Tool Function Main Toolbar Connects to sonar head. Opens an existing .331 data file to play back. Saves real-time acquire

Strona 9

1. OPERATIONAL OVERVIEW 91.6 Display Indications Below are all the indications which appear on the display screen. 2Ship's Course :Ship's S

Strona 10 - 1.2 Underwater Unit

1. OPERATIONAL OVERVIEW 101.7 Pop-up Windows The TS-331A provides convenient pop-up windows from which to conduct various operations for the vertical

Strona 11 - 1. OPERATIONAL OVERVIEW

112. SONAR OPERATION 2.1 Choosing a Sonar Mode The TS-331A has three sonar display modes: polar, sector and locked. Choose desired mode from the Mo

Strona 12 - 1.3.2 Shutting down

The paper used in this manualis elemental chlorine free. Your Local Agent/Dealer Your Local Agent/Dealer9-52 Ashihara-cho,9-52 Ashihara-cho,Nishinomiy

Strona 13

2. SONAR OPERATION 122.1.2 Sector mode This mode is used for operating the sonar to scan in a sector area. The transducer location is in the middle o

Strona 14 - 1.5 Screen Layout

2. SONAR OPERATION 132.1.3 Locked mode This mode functions to operate the sonar as an echo sounder, with the transducer locked at 0° sector size. The

Strona 15 - 1.5.2 Toolbars

2. SONAR OPERATION 142.2 Adjusting the Sonar Image from the Vertical Sonar Settings Dialog Box The vertical sonar settings dialog box contains all t

Strona 16

2. SONAR OPERATION 152.2.2 Adjusting gain Adjust the gain from the Data Gain combo box. The gain range is 0-100(%). Data gain is used to increase or

Strona 17 - 1.6 Display Indications

2. SONAR OPERATION 162.3 Monitoring Trawl Position The Locked mode can be a valuable tool for monitoring trawl location in order to prevent damage t

Strona 18 - 1.7 Pop-up Windows

2. SONAR OPERATION 174. The ship has accelerated to clear a shoal. The trawl is rising off the bottom and the bottom is displayed as if it has a sha

Strona 19 - 2. SONAR OPERATION

2. SONAR OPERATION 182.4 Drawing Lines and Symbols Using the draw tool bar or the Draw menu, you can draw lines and symbols on the sonar display (

Strona 20 - 2.1.2 Sector mode

2. SONAR OPERATION 192.4.3 Choosing line/symbol color The default line/symbol color is white. However, you may choose line/symbol color as desired.

Strona 21 - 2.1.3 Locked mode

2. SONAR OPERATION 202.5 Finding Range and Bearing from Own Ship to a Point Choose Range / Bearing from the Draw menu or click the button on the

Strona 22 - Sonar Settings Dialog Box

2. SONAR OPERATION 212.7 Choosing Display Color You may choose the color arrangement for the vertical sonar image. Open the Color Table menu and che

Strona 23

iSAFETY INSTRUCTIONSDo not place liquid-filled containers onthe top of the surface processor unit.Fire or electrical shock can result if a liquidspi

Strona 24

2. SONAR OPERATION 222.8 Grid You may configure the grid on the vertical sonar display as desired from the Grids menu. Grids menu, Scale Options,

Strona 25

2. SONAR OPERATION 232.9 Unit of Depth, Range Measurement The unit of depth/range measurement may be chosen from meters, feet and fathoms, on the Op

Strona 26 - 2.4.2 Drawing a line

2. SONAR OPERATION 242.11 Recording Sonar Data You may save real-time data to a file. To save real-time data, do the following: 1. Choose Record S

Strona 27

2. SONAR OPERATION 25Once a sonar data file has been opened, the operation of real-time sonar data acquisition will terminate. Although only one sona

Strona 28 - 2.6 Zoom

2. SONAR OPERATION 262.13 Saving, Loading System Configuration 2.13.1 Saving system configuration You may save sonar settings, window layouts and s

Strona 29 - 2.7 Choosing Display Color

273. ECHO SOUNDER OPERATION 3.1 Echo Sounder Image The echo sounder image is displayed in the echo sounder window at the right side of the screen.

Strona 30 - 2.8 Grid

3. ECHO SOUNDER OPERATION 283.2 Adjusting the Echo Sounder Image from the Sounder Settings Dialog Box The echo sounder settings dialog box contains

Strona 31 - 2.10 Noise Filter

3. ECHO SOUNDER OPERATION 293.3 Using the Echo Sounder Image to Monitor Trawl Location If the ground rope is positioned in the coverage area of the

Strona 32 - 2.11 Recording Sonar Data

3. ECHO SOUNDER OPERATION 303.4 Drawing Lines and Symbols The procedure for drawing lines and symbols on the echo sounder is similar to that for t

Strona 33

314. DEPTH/TEMPERATURE DISPLAY The depth and water temperature display graphs depth and water temperature, from right to left across the screen. Thi

Strona 34

ii TABLE OF CONTENTS FOREWORD ...iii SYSTEM CONFIGURATION ...iv OPERATIONAL INFORMATION ...

Strona 35 - 3. ECHO SOUNDER OPERATION

4. DEPTH/TEMPERATURE DISPLAY 324.2 Setting Depth/Temperature Limits You may set the depth and temperature display limits with Depth/Temp Limits on t

Strona 36 - Sounder Settings Dialog Box

4. DEPTH/TEMPERATURE DISPLAY 334.4 Depth/Temperature Scale Text Size You may choose the size of the depth/temperature scale text with DT Scale Text

Strona 37 - Location

4. DEPTH/TEMPERATURE DISPLAY 34This page intentionally left blank.

Strona 38 - 3.7 Colors

355. MENU DESCRIPTION This chapter provides menu information not discussed in previous chapters. 5.1 File Menu Connect to Sonar head Use this comm

Strona 39 - 4. DEPTH/TEMPERATURE DISPLAY

5. MENU DESCRIPTION 365.2 View Menu Clear Screen Use this command to clear the image in one of vertical sonar, echo sounder and DT (Depth/Temperature

Strona 40 - 4.3 Depth/Temperature Offset

5. MENU DESCRIPTION 375.3 Communication Menu Choose Sonar Com Port Choose another serial communication port for sonar data acquisition. Choose desir

Strona 41

5. MENU DESCRIPTION 385.5 Options Menu Color Threshold The Color Threshold dialog box allows the user to adjust the color table for the echo sounder

Strona 42

5. MENU DESCRIPTION 395.6 Help Menu The Help menu offers the following commands, which provide you assistance with this application: Help Topics P

Strona 43 - 5. MENU DESCRIPTION

5. MENU DESCRIPTION 40This page intentionally left blank.

Strona 44 - 5.2 View Menu

416. CATCH SENSOR OPERATION 6.1 Catch Sensor Dialog Box The Catch Sensor Setup dialog box provides a tool for you to configure the catch sensors o

Strona 45 - 5.4 Sonar Menu

iiiFOREWORD Introduction FURUNO Electric Company thanks you for considering and purchasing the TS-331A Wired Trawl Sonar. We are confident you will

Strona 46 - 5.5 Options Menu

6. CATCH SENSOR OPERATION 42Catch Sensor relative position (edit boxes) Input the relative length between two catch sensors in meters. Total Length

Strona 47 - 5.6 Help Menu

6. CATCH SENSOR OPERATION 436.3 Testing for Switch Activation To test for proper switch activation, do the following: 1. Submerge the unit in SALT

Strona 48

6. CATCH SENSOR OPERATION 446.6 Installing the Batteries and O-ring The catch sensor is powered by three “D” alkaline batteries and battery life i

Strona 49 - 6. CATCH SENSOR OPERATION

6. CATCH SENSOR OPERATION 453. Pull out the battery cap together with the main housing from the polyurethane housing. BatteryCapMainHousing Main h

Strona 50 - 6.2 Catch Sensor Window

6. CATCH SENSOR OPERATION 468. Use your finger to remove the O-ring from the battery cap. O-ring Battery cap, inside view 9. Coat the O-ring seat a

Strona 51 - 6.4 Flashing LED Sequence

477. MAINTENANCE & TROUBLESHOOTING ELECTRICAL SHOCK HAZARDDo not open the surfaceprocessor unit.Only qualified personnelshould work inside theeq

Strona 52 - • Slotted-head screwdriver

7. MAINTENANCE & TROUBLESHOOTING 487.3 Replacement of Internal Battery A lithium battery on the Mother Board inside the Surface Processor Unit p

Strona 53 - Main housing and battery cap

6. MAINTENANCE & TROUBLESHOOTING 493. Unscrew the connector and then connect the test cable as shown below. BLK WHT (CABLE-)

Strona 54 - 6. CATCH SENSOR OPERATION

7. MAINTENANCE & TROUBLESHOOTING 507.5 Troubleshooting The table below provides simple troubleshooting procedures which the operator may follow t

Strona 55 - TROUBLESHOOTING

6. MAINTENANCE & TROUBLESHOOTING 517.6 Diagnostic Test The diagnostic test, which is mainly for use by service technicians, checks the equipment

Strona 56 - • Silicone spray

ivSYSTEM CONFIGURATION PC Monitor(User supply)Surface Processor UnitWinchPowersource100-240VAC1φ, 50-60 HzUnderwater UnitCatch Sensor (option)(4 max

Strona 57 - SOCKET VIEW

7. MAINTENANCE & TROUBLESHOOTING 527.6.2 Diagnostic test description Header: Sent by the sonar system (wet end) to tell the Processor what kind

Strona 58 - 7.5 Troubleshooting

53MENU TREE Connect to Sonar HeadOpen File to PlaybackRecord Sonar DataStop Data RecordingSave ConfigurationLoad ConfiguruationPrintPrint PreviewPri

Strona 59 - 7.6 Diagnostic Test

APPENDIX 54SymbolLineRange/BearingMeasure Target Height (no use.)Clear Line ArtStop DrawingChoose Line Symbol ColorDrawPolar, Sector, LockedModeChoos

Strona 60

FURUNO TS-331A SP-1 E1321S01A00 SPECIFICATIONS OF WIRED TRAWL SONAR TS-331A 1. GENERAL 1.1 Display PC monitor (SXGA

Strona 61 - MENU TREE

This page is intentionally left blank.

Strona 62 - APPENDIX

IN-1 INDEX B Battery installation (catch sensor)... 44 Battery replacement ...48 C Catch sensor batter

Strona 63

INDEX IN-2P Play back speed buttons ... 24 Playing back sonar data file progress bar...

Strona 64

vOPERATIONAL INFORMATION The following may occur during operation. Follow the recommended procedure to restore normal operation. Cannot restore uni

Strona 65

viThis page intentionally left blank.

Strona 66

11. OPERATIONAL OVERVIEW 1.1 Surface Processor Unit The Surface Processor Unit (sometimes referred to as “Processor”) has a built-in PC mother boar