SATELLITE COMPASSSC-50/110
67) ALARM display This menu sets the ALARM port signal. When ALARM MODE is set to “STOP,” the alarm signal is not sent out after acknowledgement. Whe
7The display consists of four indications; a circular graph which shows direction where the tracking error rate is the highest, a bar graph which sho
810) MESSAGE display Error messages appear in the display. If RATE ERROR! appears, first check Installation Setup menu for correct setting: “Mounting
93. Replacement of Battery The processor unit has a battery which backs up the RAM contents when the power is removed. When the voltage of the batter
105. Program Upgrade The three programs are used for the SC-50/110. Two programs are used in the processor unit and one program is in the display uni
112) CPU board (Display unit) To upgrade the program on the CPU board; 1. Connect the serial port of the PC to J15 on MAIN board in the processor uni
126. Maintenance 6.1 Adjustment 1) PWR board Switching regulator frequency is adjusted on PWR board, 20P8181 as below. Test Point GND Rating Adju
137. Location of Parts Rate Sensor (Default: Pitch) GPS Receivers (1, 2, 3 from Top) Rate Sensor (Default: Roll) Rate Sensor (D
14Fig.19 MAIN Board, 20P8178BT1 (CR2450-F2ST2L) Roll (above) Pitch Log/Alarm Beacon Ext Data
15 J2 to J7 Appendix 1 Protection of ICs in Data Output Circuit Appendix 1 describes how to prevent ICs in the data output circuit temporarily. Refe
The paper used in this manualis elemental chlorine free.FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,9-52
16 1. Fabrication of Signal Cable The signal cable is fabricated as below. DO NOT hold back the cable shield over the armor. The installation manual
17 2. Grounding Cable Shield Ground the cable shield or grounding wire to the chassis by using the screw fixing the MAIN board, 20P8178 to the chassi
18 3. Adding Zener Diodes Zener diodes are added to the data output circuit as below. 1. Fabricate the diode as shown in the figure below.
19 Reference) The following waveforms show the effectiveness of the modification. With the SC-50/110 processor unit being not modified, a spike noise
20 Appendix 2 Modification on Data Output Circuit Appendix 1 describes the tentative remedy to prevent U1, U2, and U3 in the heading output circuit f
APPROVEDCHECKEDDRAWNDWG.NO.MODELUNITSC-501/1101 演算部PROCESSOR UNITSC-50/110S.kubotaT.Yoshida 06 Sep.2005 06 Sep.2005 06 Sep.2005 H.KuwamuraC 7
APPROVEDCHECKEDDRAWNDWG.NO.MODELUNIT SC-303-TSC-50S.kubotaT.Yoshida06 Sep.200506 Sep.200506 Sep.2005H.KuwamuraGPS クウチユウセンブRADOME ANTENNA UNITC 7251-
DCBA654321演算部表示部DISPLAY UNITPROCESSOR UNITCABLE W/ YEL-LINE黄線入ケーブル赤線入ケーブルCABLE W/ RED-LINEANTENNA UNIT空中線部SC-603ANT 1ANT 2ANT 3SC-501SC-502カラーマーク無NO C
Contents 1. Overview ... 1 2. Maintenance Menu...
11. Overview The satellite compass, SC-50/110 calculates the heading by using the carrier signal of the GPS satellite signals. The system also calcul
22. Maintenance Menu The system provides TEC menu or Maintenance menu for servicing. To show TEC menu, press and hold down MENU and ENT keys simultan
3Shows difference between GPS and rate sensor. Shows an error. 1: error, 0: no error 1 normally Factory use Factory use 2) COMPASS display MASK-EL
44) R-CALIB display R-CALIB (Rate sensor Calibration) is used to enter the calibration value of the rate sensor at factory. It is not necessary to
5Number of consecutive errors (For example, an error message appears with three consecutive ROL errors.) 5) RATE ERR display This menu sets the level