Installation Manual
NAVIGATIONAL ECHO SOUNDER
FE-700
IMPORTANT NOTICE ......................................................................................................i
SAFETY INSTRUCTIONS...............................................................................................ii
EQUIPMENT LISTS .......................................................................................................iii
SYSTEM CONFIGURATION..........................................................................................iv
1. MOUNTING.................................................................................................................1
1.1 Category of Equipment ........................................................................................................................... 1
1.2 Display Unit............................................................................................................................................. 1
1.3 Transducer ..............................................................................................................................................4
1.4 Distribution Box .......................................................................................................................................6
1.5 Matching Box .......................................................................................................................................... 7
1.6 Digital Depth Indicator FE-720 (option)................................................................................................... 7
1.7 Transducer Switch Box EX-8 (option) ..................................................................................................... 9
1.8 Gate Valve GV-50B-6B, GV-200B-8B (option)........................................................................................ 9
2. WIRING .....................................................................................................................11
3. CHANGING POWER SPECIFICATIONS..................................................................20
4. ADJUSTMENTS........................................................................................................22
4.1 Transducer Setting................................................................................................................................ 22
4.2 Setting the Time .................................................................................................................................... 24
PACKING LISTS………………………………………………… .......................…………A-1
OUTLINE DRAWINGS…………………………………………… ...................…………..D-1
INTERCONNECTION DIAGRAMS……………………………................... …………….S-1
www.furuno.co.jp
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Przeglądanie stron 0
1 2 3 4 5 6 ... 59 60

Podsumowanie treści

Strona 1 - FE-700

iInstallation Manual NAVIGATIONAL ECHO SOUNDER FE-700 IMPORTANT NOTICE ...

Strona 2 - All rights reserved

4F type Flush Mount Kit (F): OP02-79-1 (001-229-290) OP02-79-2 (001-229-300) OP02-79-3 (001-229-310) No. Name Type Code no. Qty Remarks 100-279

Strona 3 - SAFETY INSTRUCTIONS

51.3.1 Mounting Location To decide the location of the transducer, the following points should be taken into account. • The most important matter is

Strona 4 - EQUIPMENT LISTS

67. It is recommended to enclose the transducer cable in a conduit pipe for waterproofness and electrical shielding as well as for protecting

Strona 5

71.5 Matching Box The matching box should be selected depending on the transducer type; • 50B-6B transducer: MB-502 • 200B-8B transducer: MB-504 F

Strona 6 - SYSTEM CONFIGURATION

8F type Use the accessories FP65-00401 (See page A-7). 1. Prepare a cutout in the mounting location whose dimensions are 183 (W) x 92 (H) mm. 2. A

Strona 7 - 1. MOUNTING

91.7 Transducer Switch Box EX-8 (option) If two transducers are installed, the transducers switch box is required. Locate the transducer switch box

Strona 8 - 1.2.3 Desktop mounting

104. Grease (supplied) both sides of the gasket 1 and the inner side of the spacer. Place the gasket 1 onto the spacer. 5. Clean the flange side o

Strona 9 - 1.2.4 Flush mounting

112. WIRING Wiring Connect three cable assemblies (supplied) between the display unit and distribution box. See the interconnection diagram for deta

Strona 10 - 1.3 Transducer

12When the Transducer Switch Box EX-8 or Distribution Box MB-1200 is used, the interconnections are as follows. 12345678910123456789101212345 TB1TB

Strona 11 - 1.3.1 Mounting Location

13Cable Fabrication of DPYCYS-2.5, DPYCYS-1.5, MJ-A3SPF0015-100C , FM-C6FPS0002-100 and TPYCYS-1.5 Fabricate the power and other cables as illustrat

Strona 12 - 1.4 Distribution Box

The paper used in this manualis elemental chlorine free.・FURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPANTelephone :

Strona 13 - Overhead

14ArmorVinyl sheathCoreS=1.5 mm =1.56mm DPYCYS-1.5 sectional viewArmorVinyl sheathShield2Shield2Several cables are required to supply at local. In

Strona 14

15Cable Fabrication of TTYCYS-4 TTYCYS is a Japan Industrial Standard (JIS) cable. Use the equipment one. Vinyl SheathShield CoresArmorFold back shi

Strona 15

162 Rotate31Terminal Board TB1, TB3 Cross sectionInsert4Special tool forconnecting wires,fitted inside theDistribution BoxAnticorrosive sheathArmo

Strona 16 - Flange 2

17Transducer Connect the transducer cable to the distribution box. If necessary, attach the junction box between the distribution box and matching

Strona 17 - FE-702 Top view

18Alarm system connection The power error and shallow water alarms, which produce audio and visual alarms in the event of power failure and shallow

Strona 18 - DISTRIBUTION BOX

19Case2: Silencing the alarm from the digital depth indicator FE-720 When the main display unit FE-701 activates an alarm, it can be deactivated at

Strona 19 - Fabrication of cables

203. CHANGING POWER SPECIFICATIONS This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100 VAC, 110-115 V

Strona 20 - TPYCYS-1.5 sectional view

2124 VDC Ship's Mains 1. Remove the cover of the distribution box. 2. Remove P3 connector from J4 on the CONE Board. 3. Reattach P3 connecto

Strona 21

22 4. ADJUSTMENTS This section provides the procedures for initial set up of the equipment. The type of transducer used should be properly set bef

Strona 22 - Display unit

23 Note: If CHANGEOVER is set for MANUAL, select SINGLE. 49.6020406080m49.6BELOW SURFACE049.6mBELOW SURFACE20406080 SINGLE: Single frequency

Strona 23 - Transducer

iWARNINGTurn off the power at the switchboardbefore beginning the installation.Fire or electrical shock can result if thepower is left on.Do not ins

Strona 24 - Alarm system connection

24 4.2 Setting the Time 1. Open the system menu 2 referring to the operator’s manual. SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL E

Strona 25 - FE-720 setting

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 26 - SPECIFICATIONS

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 27 - 24 VDC Ship's Mains

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 28 - 4. ADJUSTMENTS

%1&'016;2'(2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105#%%&apo

Strona 29 - BELOW SURFACE

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 30 - 4.2 Setting the Time

%1&'016;2'52+6'/010#/'1(2#46176.+0'&9)01142'45'62'48'552#4

Strona 34

ii EQUIPMENT LISTS Standard Supply Name Type Code no. Qty Remarks Display Unit FE-701 - 1 w/Installation Materials CP02-06400 (000-015-872) a

Strona 45

iii Name Type Code no. Qty Remarks MF-22L-1-100V 000-069-401 100 VAC-120 VAC, Flush mount type MF-22L-1-200V 000-069-403 200 VAC-240 VAC, Flush mo

Strona 46

Y. HataiD-13

Strona 47

Y. HataiD-14

Strona 48

Y. HataiD-15

Strona 49

Takahashi.TD-16

Strona 51

Y. HataiD-18

Strona 52

Apr.28'06T.MAtsuguchiD-19

Strona 53 - Takahashi.T

Apr.28'06T.MatsuguchiD-20

Strona 54

DA1BC65243NAME名称TITLEMASSDWG.No.DRAWNCHECKEDAPPROVEDSCALEkg*3. FITTED AT FACTORY.*2. OPTION.*3)工場にて取付済み。*2)オプション。*1. SHIPYARD SUPPLY.*1)造船所手配。50kHzのとき

Strona 55

FE-700123456NORMAL CLOSENORMAL OPENRELAY COMMONEIA232-TDEIA232-RDGNDTB19RD1-ARD1-B 1078TD1-ATD1-B12345691078TD1-ATD1-BGND+24V0VTD1-ATD1-B+24V0VGNDTB3*

Strona 56 - T.MAtsuguchi

iv SYSTEM CONFIGURATION DISTRIBUTIONBOX FE-702DISPLAY UNITFE-701Navigation DevicePersonal Computer: Standard Supply: Optional Supply: Local Supply

Strona 57 - T.Matsuguchi

NOTE注記*3)コネクタケースでアースをとる。*3: GROUND THRU CONNECTOR CLAMP.*3FM14-7P*1FE-702DISTRIBUTION BOX分配箱243A1BCMASS名称NAMETITLEREF.No.PP-505-FEINTERCONNECTION DIAG

Strona 58 - 25/Mar/09 R.Esumi

11. MOUNTING NOTICEDo not apply paint, anti-corrosive sealantor contact spray to coating or plastic parts of the equipment. Those items contain orga

Strona 59 - Apr.17'07 R.Esumi

2• Mount the unit where shock and vibration are minimal. • Keep the unit away from electromagnetic field-generating equipment such as motors and

Strona 60 - Jan. 5'07 R.Esumi

3Dummy cover5x20 tapping screws 1.2.4 Flush mounting There are two types of flush mount kits, F type and S type. For details, see the outline diagr