INSTALLATION MANUAL
COLOR DGPS/PLOTTER GP-1850D
COLOR GPS PLOTTER GP-1850
Safety Instructions for the Installer .......................i
Equipment Lists .....................................................ii
System Configuration ...........................................iv
1. Installation of Standard Equipment ...............1-1
1.1 Installation of Display Unit ..............................................1-1
1.2 Installation of Antenna Unit .............................................1-3
2. Wiring ...............................................................2-1
3. Initial Settings..................................................3-1
3.1 NMEA Setting ..................................................................3-1
3.2 Output Data Sentences .....................................................3-3
3.3 Antenna Height.................................................................3-4
3.4 Baud Rate Setting (GP-1850D only)................................3-4
3.5 Beacon frequency Setting (GP-1850D only)....................3-5
4. Installation of DGPS Beacon Receiver
(for GP-1850)....................................................4-1
PACKING LIST .................................................... A-1
OUTLINE DRAWINGS......................................... D-1
INTERCONNECTION DIAGRAM ........................ S-1
SCHEMATIC DIAGRAM ...................................... S-2
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - COLOR GPS PLOTTER GP-1850

INSTALLATION MANUALCOLOR DGPS/PLOTTER GP-1850DCOLOR GPS PLOTTER GP-1850Safety Instructions for the Installer ...iEquipment Lists .

Strona 2 - G : MAY 11, 2001

2-12. WiringAll wiring are terminated at the rear of the display unit.ANT XDRTEMP/SPDDGPSNMEA+ GND1 32-12 - 24VDCDISPLAY UNITGroundEarth terminalANT

Strona 3 - SAFETY INSTRUCTIONS

2-2Antenna unitConnect the antenna cable to the ANT connector.GroundThe display unit contains several CPUs.While they are operating, they radiatenoise

Strona 4 - Equipment Lists

2-3How to attach the N-P-8DFB connectorOuter SheathArmorDimensions in millimeters.Inner Sheath ShieldRemove outer sheath and armor by the dimensions s

Strona 5

3-13. Initial Settings3.1 NMEA SettingNMEA port1. Press the [MENU] key.2. Press the software key labeled "CONFIGURATION".3. Press the softwa

Strona 6 - System Configuration

3-2DGPS port1. Press the [MENU] key.2. Press the software key labeled "CONFIGURATION".3. Press the software key labeled "SETUP NMEA/DGP

Strona 7 - TM-166 No.18 black

3-33.2 Output Data SentencesSelect output data sentences for external equipment as follows:.1. Press the [MENU] key.2. Press the software key labeled

Strona 8 - Flush mounting

3-43.3 Antenna Height1. Press the [MENU] key.2. Press the software key labeled "GPS/DGPS/TD OPTIONS".3. Press the software key labeled "

Strona 9 - Gasket (reddish brown)Washer

3-54. Confirm that "ON" is selected at "DGPS MODE" field forGP-1850D.5. Select "BEACON BAUD RATE" by the arrow key.6.

Strona 10 - 2. Wiring

3-64. Select "BEACON FREQUENCY" by the arrow key.5. Press the software key labeled "EDIT" to display the following message.BEACON

Strona 11 - Figure 2-3 Cable extension

4-14. Installation of DGPS Beacon Receiver(for GP-1850)The DGPS beacon receiver GR-7000A can be incorporated in the GP-1850 to provide itwith DGPS cap

Strona 12

C 9-52, Ashihara-cho, Nishinomiya, Japan Telephone: 0798-65-2111 Telefax: 0798-65-4200 Your Local Agent/Dealer All rights res

Strona 13 - 3. Initial Settings

4-2DisassemblyProcedure1. Turn off the power. Wait at least one minute before opening the cover, to allowcapacitors to discharge.2. Remove nuts attach

Strona 14 - VER 1.5

4-3Installation of DGPS receiverProcedure1. Dismount chassis assembly from panel/chassis assembly by disconnecting theconnector and PH8P from J8 on MA

Strona 15 - 3.2 Output Data Sentences

4-4 Handling of Coaxial Cable• Do not touch the connector with bare hands;use gloves.• Use radio pincers to remove, and pull outstraightl

Strona 16 - 3.3 Antenna Height

4-57. Wire cable assembly as shown in the figure below.Reattach this tape asshown right after the DGPS connection.To J8 ofANLG BoardGN-7707J1GR-7000AJ

Strona 17 - DGPS ALARM OFF

4-6Chassis AssemblyAPanel Assembly8P connectorto J8Aview6P connectorto J7J7J8PanelAssemblyAttach two ties (CV-100, supplied).Figure 4-8 Attaching chas

Strona 18 - MANUAL s 284.0kHz

4-7Checking the DGPS installation1. Press the [MENU] key.2. Press the software key labeled "CONFIGURATION".3. Press the software key labeled

Strona 19 - (for GP-1850)

4-8Connecting DGPS beacon receiverA DGPS beacon receiver whose output format is RS-232C can be connected tothe GP-1850.Below is the example of interco

Strona 23

iiiiiiiiiiiiiiGround the equipment toprevent electrical shockand mutual interference.Confirm that the power supply voltageis compatible with the volta

Strona 34

iiEquipment ListsStandard supply.ONemaNepyT.oNedoCytQskrameR1tinuyalpsiD0581-PG-10581-PGrofD0581-PG- D0581-PGrof2tinUannetnA710-APG-10581-PGrof810-AP

Strona 36

iiiOptional equipment (con't).ONemaNepyT.oNedoCskrameR9tinUannetnAS810-APG264-140-000D0581-PGrof610-APG635-140-0000581-PGrofS910-APG455-140-000D0

Strona 37

ivSystem ConfigurationThe GP-1850/1850D mainly consists of a display unit and a GPS antenna. A DGPSbeacon receiver is provided inside the display uni

Strona 38

1-11. Installation of Standard Equipment1.1 Installation of Display UnitMounting considerationsThe display unit can be installed on a tabletop, on the

Strona 39

1-2Mounting procedureFollow the procedure below to mount the display unit on a tabletop or the over-head.Tabletop, overhead mounting1. Fix the hanger

Strona 40

1-3Flush mountPan head screws (Cutout for flush mount)147 0.589 0.5143 14.550244 115 0.5238 1242 0.56-R2.25Figure 1-3 Flush mounting of