Furuno FR-2155 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria żeglarskie Furuno FR-2155. Furuno FR-2155 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 89
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - MARINE RADAR

MARINE RADARMODELFR-2155

Strona 2 - H : JUN. 7, 2001

1-2• The scanner unit is normally mounted with the gland side (cable entry side)facing the ship’s stern. If this direction is not possible, the gland

Strona 3 - SAFETY INSTRUCTIONS

1-3Scanner unit assemblingThe scanner radiator and the scanner housing are shipped in separate packagesand must be assembled at installation. Assembl

Strona 4

1-4Scanner unit mountingThe scanner unit should be assembled before hoisting it to the mounting platform.When using a crane or hoist, lift the unit b

Strona 5 - TABLE OF CONTENTS

1-5Seal washerCorrosion-proof rubbermatHex boltHex nutSpring washerFlat washerGroundwireFlat washerHex boltHex nutSpring washerFlat washerGroundwireS

Strona 6 - EQUIPMENT LISTS

1-61.2 Display UnitBefore mounting the display unitIf Gyro Converter GC-8 (option) is to be used, install and setup the GYRO CON-VERTER Board before

Strona 7 - Optional Equipment

1-74. While one person is holding the mounting base at the sides, pull the handle onthe underside of the control head to draw the display unit toward

Strona 8 - SYSTEM CONFIGURATION

1-8b)While pushing the stopper, set the catch on the display unit in the hole at thefront edge of the stay.CatchStopperStayFigure 1-7 Setting catch t

Strona 9 - MOUNTING

1-9J105J104J103J466J462J465*Screw(M3x8, 5 pcs.)****Slide forward.Screw (M4x8, 2 pcs.)Fixing hole (front)Fixing hole (rear)KnobFigure 1-9 How to remov

Strona 10 - Magnet fixing

1-10Separate Control Head Kit (Type: OP03-151, No.: 008-485-530)emaNepyTytQ.oNedoCskrameR.yssAelbaCP1/P02BS642LU1218-041-0002249S30,m01eldnaH4-C-2401

Strona 11 - Scanner unit assembling

1-118. Unfasten four screws fixing the right and left brackets on the control head.9. Unfasten four screws fixing the right and left covers on the di

Strona 12 - Scanner unit mounting

C 9-52, Ashihara-cho, Nishinomiya, Japan Telephone: 0798-65-2111 Telefax: 0798-65-4200 Your Local Agent/Dealer All rights re

Strona 13 - Flat washer

1-12KB BOTTOMPLATEP312 FX ConnectorP314 XH3PJ312 (underside)J314 (underside)ScrewM4X8 (8 pcs.)Pan-head Screw M4X8 (2 pcs.)Be careful not to pinch c

Strona 14 - 1.2 Display Unit

1-138. Lower the monitor.9. Attach the monitor front cover (option) to the place the panel cover have been,using the screw for the panel cover.10.Att

Strona 15 - Figure 1-5 Display unit

1-141.3 Power Supply UnitsThe Power Supply Unit PSU-001 (for scanner unit) and PSU-004 (for display unit)do not contain usual operating controls. The

Strona 16 - Figure 1-8 Stay fixed

2-1WIRING2.1 Scanner UnitPreparationsOpen the port side cover of the scanner unit to access terminal boards.Fabricating signal cable S03-801. Shorten

Strona 17 - Separating the control head

2-26. Determine the length of each core considering its location on STB-1 in thescanner unit (see the interconnection diagram on page S-1). Remove ap

Strona 18 - MB 03P9251

2-3Fabricating signal cable 250V-MPYCY-16 (JIS cable)1. Unfasten the clamping gland from the upper cable gland, and remove thegasket and flat washers

Strona 19

2-47. Secure the clamping gland to the cable gland body; then seal with putty.8. Connect the conductors to STB-2 and STB-3, referring to the intercon

Strona 20 - Figure 1-15 Control head

2-52.2 Display UnitTwo cables are terminated at the display unit: the signal cable S03-80 and thepower supply cable from the Power Supply Unit PSU-00

Strona 21 - Attachment of hood

2-6Leading in cables to the display unitThe cable clamp may be positioned within the display unit (default arrangement),outside the display unit. Whe

Strona 22 - 1.3 Power Supply Units

2-7Cable fed from outside display unit(B) Power clamp(Aluminum)(C) Signal clamp(Aluminum)(D) Rear clamp plate(A) Rear clamp baseBottom clamp front pl

Strona 23 - 2.1 Scanner Unit

iSAFETY INSTRUCTIONSDo not open the equipmentunless totally familiar withelectrical circuits andservice manual. Only qualified personnel

Strona 24 - Photo No.2872

2-8ConnectionsOpen the display unit and fix it with the stay. (For procedure see page 1-6.)Remove the shield cover from the INT Board. Connect signal

Strona 25

2-9Connectors on the INT BoardTable 2-1 Connectors on the INT BoardemanlangiSnoemaNbcprotcennoC.onrotcennoCepytelbacilppAtnempiuqeskrameRlangiStupnIl

Strona 26 - Fixing the scanner cover

2-10How to attach NH connector20mm1 Insert NH connectorwire into NH connectorhousing.2 Cut shrink tubingin 20 mm lengths andslip onto each wire.3 Sol

Strona 27 - 2.2 Display Unit

2-112.4 Power Supply UnitsPower supply unit PSU-004Thermal relayK2Relay K3Relay K1TBPTB12TBPTB13TBPTB11TBPTB14Photo No. 3148Figure 2-15 Power supply

Strona 28 - (Display unit, rear view)

2-12Power supply unit PSU-001Two cables run to the Power Supply Unit PSU-001, the power cable (DPYCY-3.5) and the signal cable (660V-MPYCY-16). The f

Strona 29

3-1INITIALIZATION AND ADJUSTMENT3.1 Tuning InitializationTune the radar as follows: Press [RADAR MENU] [0] [0] [2] [0] [0] [0] [0] (TUNEINITIALIZE on

Strona 30 - Connections

3-23.4 Heading AlignmentYou have mounted the scanner unit facing straight ahead in the direction of thebow. Therefore, a small but conspicuous target

Strona 31 - Connectors on the INT Board

3-33.5 Adjusting Sweep TimingSweep timing differs with respect to the length of the signal cable between thescanner unit and the display unit. Adjust

Strona 32 - How to attach NH connector

3-43.7 Confirming Magnetron Heater VoltageMagnetron heater voltage is adjusted at the factory using a 15 m signal cable.Therefore, when the length of

Strona 33 - 2.4 Power Supply Units

3-5 Fuse801R813Photo No. 2914Figure 3-6 Scanner unit, power supply unit PSU-001Note: When the length of the cable between the scanner unit an

Strona 34 - Power supply unit PSU-001

iiCAUTIONObserve the following compass safedistances to prevent deviation of amagnetic compass:Ground the equipment toprevent electrical shock andmutu

Strona 35 - INITIALIZATION AND ADJUSTMENT

3-63.8 Initial Setting MenusThe INITIAL SETTING menus (four menus) and the OWN SHIP INFORMATIONmenu setup the radar according to expected usage, auth

Strona 36 - 3.4 Heading Alignment

3-7INITIAL SETTING1 menuKeying sequence: [RADAR MENU] [0] [0] [0] [2]HL ALIGN: Aligns heading.TIMING ADJ: Adjusts sweep timing.ANT HGT: Enter height o

Strona 37 - 3.6 Suppressing Main Bang

3-8HEAD UP TB SCALE: Bearing scale may be shown in degrees or compasspoints in the head-up mode.CTR ECHO STRETCH: Turn on to enlarge echoes in the ran

Strona 38

4-1INSTALLATION OF OPTIONAL EQUIPMENT4.1 Gyro Converter GC-8The Gyro Converter GC-8, incorporated inside the radar display unit, convertsanalog gyroc

Strona 39 - Photo No. 2914

4-24) Connect the GYRO CONVERTER Board to the INT Board (cables suppliedwith GC-8) as shown below.INT Board GYRO CONVERTER BoardJ446

Strona 40 - 3.8 Initial Setting Menus

4-3Connection of external power supplyAn external power supply is necessary when the repeater signal is step-by-steptype and the step voltage is belo

Strona 41 - INITIAL SETTING3 menu

4-4Setting method 1: by gyrocompass specifications1) Gyrocompass type 2) FrequencyGyrocompasstypeSW1-4SW1-5SW1-6JP1 Frequency SW1-7SW1-8RemarksAC syn

Strona 42 - OWN SHIP INFORMATION menu

4-5Setting method 2: by make and model of gyrocompassrekaMsledoMnoitacificepSWS1-1WS2-1WS3-1WS4-1WS5-1WS6-1WS7-1WS8-1WS1-2WS2-2WS3-21PJ2PJ3PJ4PJ5PJON

Strona 43 - 4.1 Gyro Converter GC-8

4-6Location of DIP switches, jumper wires on the GYRO CONVERTERBoard64P1106JP5, JP4(Supply voltage)JP2(Rotor voltage)JP3(Stator voltage)JP1(Gyro type

Strona 44 - J465 (6P) J1 (14P)

4-74.2 ARP Board ARP-26The ARP Board ARP-26, which provides ARPA functions, is an optional circuitboard which is accommodated in the display unit of

Strona 45 - Default setting

iiiTABLE OF CONTENTSEQUIPMENT LISTS... ivSYSTEM CONFIG

Strona 46 - 5) Ratio 6) Supply voltage

4-8ARP board adjustment1. Turn the GAIN, A/C SEA and A/C RAIN controls fully counterclockwise, andthen transmit on the 12 nm range.2. Connect a digit

Strona 47

4-9Final checkConnect a gyrocompass and a log to the radar and place the radar under transmitstate. Confirm that LEDs CR9, CR10, CR11, CR12, CR15 and

Strona 48

4-104.3 RP Board RP-26The RP Board RP-26, which providesvideo plotter functions, consists of a circuitboard and a card drive both of which are accomm

Strona 49 - 4.2 ARP Board ARP-26

4-114. Unfasten the front panel from the display pedestal.5. Pass the connector from the card case through the hole in the display pedestal.Display p

Strona 50 - ARP board adjustment

4-1210.Fasten the front panel on the display pedestal.11.Retract the stay to close the display unit.12.Fasten the right arm cover.Separate type contr

Strona 51 - Final check

4-13M-card baseM-cardcase lidPan Head ScrewM2.6X5(2 pcs.)Control sectionControl sectionfront panelFigure 4-13 Display pedestal, front view5. Loosen s

Strona 52 - 4.3 RP Board RP-26

4-1410.Fasten the front panel of the display pedestal.11.Fasten the ground wire to the location shown in Figure 4-14.12.Close the monitor.4.4 Perform

Strona 53 - Figure 4-10 Display pedestal

4-154.5 Alarm KitNecessary parts: OP03-156 (Code no. 008-500-650)The alarm kit mainly consists of a circuit board and connection cables, and pro-vide

Strona 54 - Separate type control head

4-16J475J474J473J472J471J451AAPan-head ScrewM3X8, 4 pcs.Cable Tie CV-100,2 pcs.ALARM Board03P9262NH Connector03-1991(3P), 4 pcs.Pan-head screwM4X12 C

Strona 56 - 4.4 Performance Monitor PM-30

ivEQUIPMENT LISTSStandard SupplyemaNepyT.oNedoCytQskrameRtinUrennacSN-9400-BSR-A4NX–1,CAV022/002,reciedon,mm07523 ,φ W051I-9400-BSR-A4NX–,CAV022/002,

Strona 67

vOptional EquipmentemaNepyT.oNedoCytQskrameRyalpsiDetomeR0108-DMF – 1retrevnoCoryG2-8-CG025-644-800tes1redroetarapeS1-8-CG072-644-800nitliuBhctiwsret

Strona 78

viSYSTEM CONFIGURATIONDISPLAY UNITRDP-124ARPA BoardARP-26NavigatorIEC 61162-1 (Input/Output)IEC 61162-1 (Input)Speed LogOPTIONPerformanceMonitorPM-30

Strona 89

1-1MOUNTING1.1 Scanner UnitMounting considerations• The scanner unit is generally installed either on top of the wheelhouse or on theradar mast, on a

Komentarze do niniejszej Instrukcji

Brak uwag