Furuno FSV-84 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt powietrzny Furuno FSV-84. Furuno FSV-84 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 95
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - COLOR SCANNING SONAR

COLOR SCANNING SONARFSV-84www.furuno.co.jp

Strona 2 - (DAMI ) FSV-84

1-2 Compartment1200 mm 500 mm500 mm500 mm Maintenance space, example sonar compartment Note: After mounting the equipment, be sure to install anti-

Strona 3 - SAFETY INSTRUCTIONS

1-31.1.2 Shortening the retraction tank Shorten the tank as necessary so that the transducer positions well below the keel when it is fully lowered.

Strona 4

1-4 1.1.3 Remarks for installation of retraction tank 1. Install, if possible, the tank on the keel where the tank can be most firmly fixed. 2. In

Strona 5 - TABLE OF CONTENTS

1-51.1.4 Installing hull unit on retraction tank After welding the retraction tank and allowing sufficient time for cooling, install the hull unit a

Strona 6 - SYSTEM CONFIGURATION

1-6 1.1.5 Installing stays (anti-vibration measure) Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron w

Strona 7 - System with FURUNO monitor

1-71.2 Processor Unit Mounting considerations When choosing a mounting location, keep in mind the following points: • The processor unit must be mo

Strona 8 - EQUIPMENT LISTS

1-8 Mounting procedure 1. Unfasten two bolts from the bottom of the front side of the processor unit. Pull the unit toward you to separate it from t

Strona 9 - 1. MOUNTING THE EQUIPMENT

1-9Mounting procedure 1. Drill four holes of 12 mm in diameter in the mounting location, referring to the outline drawing for mounting dimensions. 2

Strona 10 - 1200 mm 500 mm

1-10 Attaching the CRT filter 1. Attach two spacers (5×2.5, supplied) with screws (M5×10, supplied) to the location shown below. 2. Screw two hood

Strona 11

1-111.4 Control Unit The control unit is designed for mounting on a tabletop, with or without the KB (keyboard) fixing plate (supplied), which mounts

Strona 12 - Thickness: at least 12 mm

The paper used in this manualis elemental chlorine free.・FURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPANTelephone :

Strona 13 - (16 places)

1-12 Control unit coverPrevious cable holeScrewM4x8 (8 pcs.)ClampScrew (M4x12)Fasten the cable with the clamp here.NutSpring washerFlat washerJ1J2Con

Strona 14

1-131.5 Transceiver Unit The length of the cable between the transceiver unit and the hull unit is 5 m, so choose a mounting location within 5 m of t

Strona 15 - 1.2 Processor Unit

1-14 1.6 Attachment Kit (option) The attachment kit permits use of the tank for the CSH-80 series. Attachment kit (Type: OP10-30, Code no.: 000-067

Strona 16 - 1.3 Monitor Unit (option)

1-15Hex. nutSpring washerFlat washerInsulation gasket (2)Insulation gasket (1)Hex. boltRetraction tankHex. boltFlat washerHull unit flangeO ringInsul

Strona 17

1-16 1.7 FRP Tank (option) Caution for installing FRP tank Use an FRP tank supplied by FURUNO. Other makes of tank may be used, however watertightne

Strona 18

1-174. Set the hull unit on the top of the retraction tank, observing the following cautions: - Clean the hull unit flange to make sure no foreign m

Strona 19 - 1.4 Control Unit

1-18 1.8 Control Box Extension Kit (option) The control box may be mounted separately from the hull unit. Detach the control box and mounting plate

Strona 20 - With KB fixing plate

1-19Fix the control box to bulkhead with four M10 bolts. GNDTERMINALCABLE CLAMPFIXING HOLETERMINAL

Strona 21 - 1.5 Transceiver Unit

1-20 This page intentionally left blank.

Strona 22 - 1.6 Attachment Kit (option)

2-12. WIRING 2.1 How to Use the Crimping Tool, Pin Extractor A special crimping tool is necessary for connection of wires to the contact pins of the

Strona 23

iWARNINGDo not install the equipment where itmay get wet from rain or water splash.Water can cause fire or electrical shock, ordamage the equipment.B

Strona 24 - 1.7 FRP Tank (option)

2-2 2.2 Wiring Monitor(Local supply)CONTROL UNIT FSV-8401CONTROL UNIT FSV-8401MONITOR UNIT FSV-2400PROCESSOR UNITFSV-8402HULL UNITFSV-8432(800 mm str

Strona 25 - Flat washer

2-3Transducer cable If the transducer cable is not quite long enough, unfasten the cable clamp shown in the figure below to release the cable. This w

Strona 26 - JUNCTION BOX

2-4 2.3 Monitor Unit (option) 2.3.1 Fabrication of cable from processor unit One of the cables 10S2074 (10 m) or 10S2075 (30 m) runs between the

Strona 27 - FIXING HOLE

2-5HousingClampWasherNutCenter PinGasket7.5Shield3Positioning guide pins Guide pins of the connector identify the mating receptacle. They are; • G

Strona 28

2-6 Assembling D-SUB connector (CN-A302) 1. Remove vinyl sheath of cores by 3 mm. 2. Pass the cores through shrink tubing (local supply). 3. Solde

Strona 29 - 2. WIRING

2-7Cable coverCable from processor unit(10S2074 or 10S2075) Cable from control unit(10S2076)ClampConnector boardCN-A306CN-A305 CN-A30434521CN-A308 CN

Strona 30 - 2.2 Wiring

2-8 2.4 Processor Unit Cables from the monitor unit, transceiver unit and other equipment are connected to the CONE Board (10P6905) in the processor

Strona 31 - Raise/lower control box

2-92.4.1 Cable from transceiver unit This cable (10S1258) runs between the processor unit and transceiver unit (FSV-841). Pass it through the cable

Strona 32 - 2.3 Monitor Unit (option)

2-10 Positioning guide pins Guide pins of the connector identify the mating receptacle. They are; • Guide pin A (Large): 1 • Guide pin B (Small)

Strona 33 - • Guide pin B (Small): 1

2-112.4.5 Optional equipment Optional equipment (navigator, current indicator, AD converter, speed log, etc.) are connected at the rear of the proces

Strona 34 - Cable clamp

ii CAUTIONMaximum speed while the transducer isprojected or being raised or loweredis as below, to prevent damage to thetransducer.

Strona 35 - Monitor unit, rear view

2-12 8 cmSoldering sideSoldering-sideConnector caseConnector case1 cm2 cm3 mmShield2 cm3mmShieldVinyl sheathVinyl sheathVinyl sheathArmorSolder unuse

Strona 36 - 2.4 Processor Unit

2-13Synchronizing with echo sounder or other sonar To synchronize the transmission of the FSV-84 with an echo sounder or other type of sonar, make co

Strona 37

2-14 2.5 Transceiver Unit 2.5.1 Fabrication of 38P connector 00-8016-038-313761HV (CN-B101) Pass the cable (10S2158) from the processor unit (FSV-84

Strona 38 - • Guide pin A (Large): 1

2-15Power cable fabrication Use power cable DPYCY-2.5 or equivalent. 140 (Power source side: 200)3530FV2-4 (2 pcs.)Vinyl sheathArmorAnticorrosiveshea

Strona 39 - CO-SPEVV-SB-C 0.2sq, 5P

2-16 PowerTo Hull Unit(cable 10S2078)To Processor Unit(cable 10S1258-1)TB-B101CN-B101CN-B102Satellite CompassTB-B10CableNo.12345678910111213141516Cla

Strona 40 - Connector case

2-172.6 Control Box of Hull Unit Connect the power cable TYPCY-4 (3φ) and the transceiver unit cable (10S2078, end with shorter peeled portion) as s

Strona 41 - Processor

2-18 FUSE FUSEF601 F602INPUT(TB-B101)FUSEF601 F602100V110V 20A 20A115V220V230V10A

Strona 42 - 2.5 Transceiver Unit

2-192.8 Controller Extension Kit (Junction Box) Wire the junction box of the controller extension kit as shown below. Cable from TB-1 in control bo

Strona 43 - Wiring WAGO connector

2-20 This page intentionally left blank.

Strona 44

3-13. ADJUSTMENT AND CHECK 3.1 Hull Unit Check Setting transmission on Default setting of transmission is OFF. Set the transmission on as follows:

Strona 45 - 3 phase power cable

iiiTABLE OF CONTENTS SYSTEM CONFIGURATION...iv EQUIPMENT LISTS

Strona 46 - 2.7 Input Voltage and Fuses

3-2 4. Choose YES and press the [MENU] key. OTHERS MENU QUITQUITQUITMARK DISPLAY...MARK SIZE...DATA DISPLAY...CURRENT VEC & WIND...NET SONDE S

Strona 47

3-33. Remove the cover of the raise/lower control box and use a multimeter to measure the following voltages: Terminal Terminal No. Voltage TB-C101

Strona 48

3-4 3.2 Heading Adjustment When the BOW mark on the flange of the hull unit cannot be directed toward ship’s bow, adjust the heading so an echo which

Strona 49 - 3. ADJUSTMENT AND CHECK

3-5 MENU QUITQUITOTHERSQUITCANCELLANGUAGE : EnglishHEADING ADJUST1 : 0°HEADING ADJUST2 : 0°PROPELLER DIREC : -180°ES2 SELECT : ESES DRAFT OF

Strona 50

3-6 3.3 Configuring Own Ship Mark Set own ship’s dimensions and the location of the transducer to accurately display the own ship mark on the displa

Strona 51 - UP MD DN

3-7Ship'sLengthShip's WidthTD Position 1TD Position 2(Negative valuefor port)5. Choose ▲ or ▼ and then operate the [MENU] key to set the sh

Strona 52 - 3.2 Heading Adjustment

3-8 CIF BAUD RATE: Set the transmission rate for the CIF port. If the CS-120A is connected, choose “2400 bps”. (2400 bps, 4800 bps, 9600 bps, 19200 b

Strona 53

3-9SPEED & COURSE: Choose the input format for ship’s speed and course data. When choosing the LOG&HEADING, the heading data is used instead

Strona 54

3-10 Data sentences NMEA Input sentences Sentence Main data source Main data GNS GPS Latitude, longitude GGA GPS Latitude, longitude RMA Loran C

Strona 55 - 3.4 Other SYSTEM Menu Items

3-113.4.3 OTHERS menu MENU QUITQUITOTHERSLANGUAGE : EnglishHEADING ADJUST1 : 0HEADING ADJUST2 : 0PROPELLER DIREC : -180ES2 SELECT : ESES DR

Strona 56 - 3.4.2 EXT DATA SETTING menu

iv SYSTEM CONFIGURATION System with locally supplied monitor Note 1: Power Kit (option, installed inprocessor unit) required to connect CS-120A.220 V

Strona 57

3-12 TRACKBALL SPEED: Choose the speed of trackball movement (inside menu window only). (SLOW, NORMAL, FAST) HULL UNIT STROKE: Choose the stroke len

Strona 58

3-133.6 DIP Switch Setting IFESSCANSCAN2DUALDCONJ1IFES board (10P6903)DCON board (10P6987)J496, J497J1J496J497DCAC Processor unit, inside view 3.6.

Strona 59 - 3.4.3 OTHERS menu

3-14 3.6.2 Choosing echosounder signal There are two kinds of echosounder signals, AC signal and DC signal. Set the appropriate jumper on the CONE b

Strona 60

4-14. CONNECTING EXTERNAL INTERFACE CS-120A The External Interface CS-120A functions to enable upgrading from a past CSH series sonar. However, we r

Strona 61 - 3.6 DIP Switch Setting

4-2 3. Fix the power supply pcb (supplied) to the power module with four spacers (supplied). 4. Connect two VH connectors (provided on the power mo

Strona 62

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 63 - INTERFACE CS-120A

CODE NO.CODE NO.CODE NO.CODE NO.007-008-780TYPETYPETYPETYPEFP10-02901略  図OUTLINE名  称 NAME数量Q'TY用途/備考REMARKS番 号 NO. 型名/規格DESCRIPTIONS1/1-0 ACCESSO

Strona 64 - OR NMEA2/CIF2

㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀%7: (58,,'0#/'176.+0'&'5%4+26+10%1&'ͳ36;࡙࠾࠶࠻ 70+6ᠲ૞ㇱ%10641.70+

Strona 65 - 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀

㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀%7: (58#$0#/'176.+0'&'5%4+26+10%1&'ͳ36;࡙࠾࠶࠻ 70+6ㅍฃାⵝ⟎64#05%'+8'470+6

Strona 66 - INSTALLATION MATERIALS

%1&'016;2'52+6'/010#/'1(2#46176.+0'&9)01142'45'62'48'552#4'91

Strona 67

vSystem with FURUNO monitor PROCESSOR UNITFSV-8402Current IndicatorE/S InterfaceVI-1100ANet SondeJunction BoxCS-170E/S InterfaceVI-1100AExternalInter

Strona 68

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 69

㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀%7: (586(5860#/'176.+0'&'5%4+26+10%1&'ͳ36;࡙࠾࠶࠻ 70+6਄ਅⵝ⟎*7..70+6(58

Strona 70 - +056#..#6+10/#6'4+#.5

%1&'016;2'52+6'/010#/'1(2#46176.+0'&9)01142'45'62'48'552#4'91

Strona 71

%1&'016;2'(58.6⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105%7

Strona 72 - (14*#..70+6

%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..

Strona 73 - ਄ਅⵝ⟎ޓ࠼࡯ࡓ᦭ࠅޔ࠲ࡦࠢήߒ

%1&'016;2'⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105#%%'5514+'5ઃዻຠ⴫ޓޓޓޓޓ

Strona 78

vi EQUIPMENT LISTS Standard supply Name Type Code No. Qty Remarks Control Unit FSV-8401-10 —1 w/10 m cable FSV-8402-100 — 110 VAC Processor Unit F

Strona 85

Nov.22'06T.MatsuguchiD-10

Strona 86 - T.Matsuguchi

Nov.22'06T.MatsuguchiD-11

Strona 88

D-16D-13

Strona 89

1-11. MOUNTING THE EQUIPMENT 1.1 Hull Unit Note 1: The raise/lower control box on the hull unit contains a motion sensor. Therefore, never drop the

Strona 91 - Mar.14'07 R.Esumi

Mar.14'07 R.EsumiD-15

Strona 92 - FURUNO ELECTRIC CO., LTD

DCBA654321FURUNO ELECTRIC CO., LTD.INTERCONNECTION DIAGRAMCOLOR SCANNING SONAR相互結線図カラースキャニングソナーFSV-84名称NAMETITLEDWG No.MASSSCALEAPPROVEDCHECKEDDRAWNkg

Strona 93

DCBA654321FURUNO ELECTRIC CO., LTD.INTERCONNECTION DIAGRAM相互結線図名称NAMETITLEDWG No.MASSSCALEAPPROVEDCHECKEDDRAWNkgT.YAMASAKI*1)造船所手配。注記*2)オプション。*3)コネクタは

Strona 94

FURUNO ELECTRIC CO., LTD.NOTE*1: SHIPYARD SUPPLY.注記*1)造船所手配。*2)オプション。*3)コネクタは工場にて取付済み。*4)00-8016-038-313761HVF*3: CONNECTOR PLUGS FITTED AT FACTORY.*4

Strona 95

CB123DADWG.No.SCALECHECKEDAPPROVEDDRAWNMASSkg名称NAMETITLEINTERCONNECTION DIAGRAM制御部外部信号接続相互結線図PROCESSOR UNIT EXTERNAL INTERFACEJ10GNDSONDE_WLGNDGNDSOND

Komentarze do niniejszej Instrukcji

Brak uwag